3.6.4 Wash down stainless cleaningRequired equipmentNoteEquipmentHigh pressure washerUsable detergentsThe stainless version is verified against the following detergents.Old designationTypeDetergentTopmaxx 421Topaz MD4DetergentP3-topax M 55Topaz CL2DetergentP3-topax 56Topaz AC3DetergentP3-topactive DESDisinfectantCleaning instructionsDANGERturn off all electrical power, hydraulic and pneumatic pressure supplies beforeentering the workspace of the manipulator.Also read the safety sections:• Safety risks related to pneumatic/hydraulic systems on page 33• Risks associated with live electric parts on page 29• Safety risks during installation and service work on robots on page 23NoteAction• Water temperature: max. 80°CPre-rinse with water for removalof rough soil with low pressure.1See figure for Sensitive spotson page 144.• Detergent: TOPAZ MD4• Concentration: 3 %• Water temperature: 40 - 60°CFoam the whole external surfacewith detergent.2Let the detergent work for ap-prox 20 minutes to retain effect-ive cleaning properties.3Ensure that the solvent does notdry on the surface.Rinse thoroughly with water.4• Detergent: P3-topactive DES• Concentration: 1 - 2%.• Water temperature: 10 - 40°C• Time approx. 20 min.Apply the disinfectant. Time,concentration, and water temper-ature are chosen to reach thedesired effect.5Rinse thoroughly with water.6Continues on next page150 Product manual - IRB 3603HAC030005-001 Revision: U© Copyright 2008-2018 ABB. All rights reserved.3 Maintenance3.6.4 Wash down stainless cleaning