Total Access 3000 DSLAM DS3 Primary Switch Module Installation and Maintenance Practice10 61181041L3-5APushbuttonsThe DS3-PSM is equipped with the pushbuttons described in Table 3.INSTALLATIONAfter unpacking the DS3-PSM inspect it for damage. If damage has occurred, file a claim withthe carrier then contact ADTRAN Customer Service. Refer to “Appendix A” Warranty” forfurther information. If possible, keep the original shipping container for returning theDS3-PSM for repair or for verification of shipping damage.Shipping ContentsThe contents include the following items:• Total Access 3000 DSLAM DS3 Primary Switch Module• Total Access 3000 DSLAM DS3 Primary Switch Module Job AidCAUTIONElectronic modules can be damaged by Electrostatic Discharge(ESD). When handling modules, wear an antistatic discharge wriststrap to prevent damage to electronic components. Place modulesin antistatic packing material when transporting or storing. Whenworking on modules, always place them on an approved antistaticmat that is electrically grounded.Table 4. PushbuttonsSwitch DescriptionAPS When pressed with the TEST/ENABLE pushbutton from the offline unit, a switch isforcedWhen activated with the TEST/ENABLE pushbutton on the online unit, toggles INHIBITstatusTEST/ENABLE When pressed alone, tests all unit LEDsWhen activated with the APS pushbutton from the offline unit, a switch is forcedPress and hold in during power up to reset module to factory defaultsC A U T I O N !SUBJECT TO ELECTROSTATIC DAMAGEOR DECREASE IN RELIABILITY.HANDLING PRECAUTIONS REQUIRED.