Total Access 3000 DSLAM DS3 Primary Switch Module Installation and Maintenance Practice32 61181041L3-5AConfiguration ScreenThe Configuration screen (see Figure 15) is read-only and displays information about thesystem. For instance, the Common Language Equipment Identifier (CLEI) Code and PartNumber can be used to search for related information on the ADTRAN website or to orderadditional parts. The software revision may be required when calling ADTRAN TechnicalSupport.Figure 15. Configuration ScreenThe Configuration screen fields are shown in Table 9.Table 9. Configuration Screen FieldsField DescriptionUnit Name This field displays the unit name of the DS3-PSM.CLEI Code This field displays the CLEI code of the DS3-PSM.Part Number This field displays the part number of the DS3-PSM.Serial Number This field displays the serial number of the DS3-PSM.Production Revision This field displays the current product revision of the DS3-PSM.App Software Rev This field displays the software revision of the DS3-PSM.Boot Software Rev This field displays the boot software revision of the DS3-PSM.Shelf: 1 Slot: B Total Access System MM/DD/YY HH:MMONLINEConfiguration Shelf 1 of 6Unit Name : DS3-PSMCLEI Code : M3C3LT0AAAPart Number : 1181041L3Serial Number : 1234567890123456789012345Product Revision : DApp Software Rev : A00.33Boot Software Rev :(N) Next Shelf, (P) Previous Shelf'?' - System Help Screen