Total Access 3000 DSLAM DS3 Primary Switch Module Installation and Maintenance Practice12 61181041L3-5APROVISIONINGAll provisioning takes place through the DS3-PSM/PCU communication link via DS3-PSMmenus and/or SNMP access to the DS3-PSM. Onboard switches or jumpers are not provided.The DS3-PSM retains all provisionable data for the ESMs on its MDE link in a nonvolatilememory device. However, the ESM retains its serial number and CLEI code.AutoprovisioningIf Autoprovisioning is enabled on the PCU, the provisioning of the previous PSM, includingService State, is written to the new PSM upon installation if the newly installed module is ofthe same device type as the previous module.Linked ProvisioningThe Linked Provisioning option transfers provisioning settings, except Service State, betweenthe online and offline modules to keep the provisioning settings on both modules identical. Achange in the Linked Provisioning status to either module is transferred to the other module,causing both modules to always have the same Linked Provisioning status. Therefore, bothmodules are either always enabled or always disabled.Autoprovisioning does not overwrite Linked-Provisioning settings received on installation.All subsequent provisioning changes are made through the PCU communications link.Default ProvisioningThe DS3-PSM default provisioning options are shown in Table 5.For detailed information on the DS3-PSM menus, refer to “Menu Descriptions” on page 31.Table 5. Default Provisioning OptionsProvisioning Option Available Options Default SettingsAdvanced ProvisioningService State In Service;Out of Service-Maintenance;Out of Service-UnassignedOut of Service-MaintenanceOAM Identification User defined NoneLinked Provisioning Enable; Disable EnableInvalid cells to exit Syncstate1-15 7Valid cells to enter Syncstate,1-15 6DS3 and Timing ProvisioningFraming C-Bit Direct Map; C-Bit PLCP;M23 Direct Map; M23 PLCPC-Bit Direct Map