5-100container Commandscontainer set failoverTo assign an automatic failover disk(s) for a single array, use thecontainer set failover command. If the array was alreadyassigned a failover disk(s), the command adds the specified disk(s)to the array’s list of failover disk(s). Although all array types acceptfailover assignments, only mirror set and RAID-5 set (redundant)array types use the failover assignment if a disk fails.Syntaxcontainer set failover {container} {scsi_device}[{scsi_device}...]Parameters{container}Specifies the ID number (0 to 63) of the array on which toassign an automatic failover disk(s).{scsi_device}Specifies the ID for the SCSI device that you want to assign as afailover disk to the array specified in the container parameter.A SCSI ID consists of a SCSI channel number (for example, 0, 1,2, 3, etc.), a SCSI device ID (0 through 15 inclusive), and a SCSIdevice logical unit number (0 through 7 inclusive). See thescsi_device section on page 3-7 for more information onhow to specify the SCSI device.{scsi_device}...Specifies the ID(s) for additional SCSI device(s) that you wantto assign as failover disk(s) to the array specified in thecontainer parameter.ExamplesBefore assigning a SCSI device as a failover disk to an array, use thecontainer list command to obtain information about anyexisting arrays.