The SmartSwitch 2000 Chassis View2-48Managing the HubSetting the UPS IDYou need to set the UPS ID typecode that indicates the manufacturer and modelof the UPS.To set the UPS ID:1. Click on next to the SET UPS ID text box. A Model number menu willappear. Scroll to highlight the appropriate UPS ID. (Consult the manual thatwas included when you purchased your UPS for the correct Model IDnumber.)2. Click on the OK button. The UPS ID you have chosen will appear in the textbox, and the UPS window will be active.If your UPS unit does not function after you have set this ID, check the manualyou received with the UPS to ensure that you have chosen the correct UPS ID. Ifyou need to change the ID, follow the directions given above.Using the Test OptionYou can use the test option to activate a self-test cycle for your unit. This self-testwill check the viability of your unit and its battery.To activate the test:1. Click on the Test button. The unit will begin its self-test. The results of the testwill appear in the Test Result text box next to the Test button.Using the Disconnect OptionYou can disconnect the UPS attached to your SmartSwitch 2000 through its comport, as follows:1. Click on the Disconnect button near the bottom of the UPS window. YourUPS will now be disconnected.To reconnect, simply click on the OK button, or close, then re-open the UPSwindow.Redirecting Traffic on the SmartSwitch 2000The Port Redirect window (Figure 2-19) allows you to redirect traffic from one ormore interfaces directly to another interface — essentially mirroring the traffic atthe “redirect” interface. This feature is useful in that it allows you to use anexternal analyzer on the “redirect” port to analyze data, without disturbing thenormal switching operations at the original source ports. The Port Redirectwindow displays the interface remap table and allows you to add new entries to