28 49-85244The door is very heavy. Be careful when removing and lifting the door.Do not lift the door by the handle.To remove the door:1. Fully open the door.2. Pull the hinge locks down toward the door frame, tothe unlocked position. A tool, such as a small flat-blade screwdriver, may be required.3. Firmly grasp both sides of the door at the top.4. Close door to the door removal position,(approximately 15 degrees from closed) and lift it upand out until the hinge arm is clear of the slot.To replace the door:1. Firmly grasp both sides of the door at the top.2. With the door at the same angle as the removalposition, seat the indentation of the hinge arm into thebottom edge of the hinge slot. The notch in the hingearm must be fully seated into the bottom of the slot.3. Fully open the door. If the door will not fully open, theindentation is not seated correctly in the bottom edgeof the slot.4. Push the hinge locks up against the front frame of theoven cavity, to the locked position.5. Close the oven door.Allow the temperature probe to cool before cleaning.The probe should be cleaned with soap and water byhand.Do not immerse the temperature probe in water.Do not store the temperature probe in the oven.Do not clean the temperature probe in the self-cleaningoven.Lift-off Oven DoorProbeCARE AND CLEANING:/LIWRII2YHQ'RRU3UREHRemovalpositionPull hinge locks down to unlockPush hinge locks up to lockReplacementpositionHinge lockSlotHinge armIndentationBottomedgeof slotHingelockHingearm