REV CJune 2005 Section 3 • Scheduled Maintenance ProceduresPart No. 52075 TMZ-34/19 3 - 13CHECKLIST B PROCEDURESB-2Inspect the Electrical WiringMaintaining electrical wiring in good condition isessential to safe operation and good machineperformance. Failure to find and replace burnt,chafed, corroded or pinched wires could result inunsafe operating conditions and may causecomponent damage.Electrocution hazard. Contactwith hot or live circuits couldresult in death or serious injury.Remove all rings, watches andother jewelry.1 Inspect the following areas for burnt, chafed,corroded and loose wires:· Turntable area· Ground controls· Turntable rotation manifold wiring· Power unit wiring· Outrigger manifold wiring (if equipped)2 Inspect for a liberal coating of dielectric greasein the following locations:· Between the ground and platform controls· All harness connectors· Level sensor3 Turn the key switch to ground control and pullout the red Emergency Stop button to the onposition at both the ground and platformcontrols.4 Raise the secondary boom until the platform isapproximately 10 feet / 3 m off the ground.5 Inspect the boom storage area for burnt, chafedand pinched cables.6 Lower the boom to the stowed position and turnthe machine off.7 Inspect the following areas for burnt, chafed,corroded, pinched and loose wires:· Boom to platform cable harness· Primary, secondary and jib booms800-610-4101ActionRental.com