REV CSection 4 • Repair Procedures June 20054 - 24 TMZ-34/19 Part No. 52075N.C.N.O.N.O.SW25DIP SWITCHSW25ADIP SWITCHD7VOLTAGEREGULATORP1EMERGENCYSTOPKS1KEYSWITCHdcba1 2 3 4 5 6 7 8ON KJ1 2 3 4 5 6 7 8ON KJeeHow toSet the DIP Switch1 Turn the key switch to the off position and pushin the red Emergency Stop button to the offposition at both the ground and platformcontrols.2 Remove the fasteners securing the top to theground controls box and open the groundcontrol box.3 Rotate the top of the ground control box to theposition shown in the following illustration tocorrectly identify the configuration of the DIPswitch settings.4 Locate the DIP switch on the circuit board.Move the DIP switch settings to correspondwith the configuration of the machine options asillustrated below.5 Close the lid and install the fasteners.DIP Switch LegendToggle Description Position1 All models On2 Hour meter/flashing beacon On3 Not used Off4 Outriggershydraulic Offmanual On5 - 16 Not usedGROUND CONTROLS1 2 3 4 5 6 7 8ON KJ1 2 3 4 5 6 7 8ON KJ1 2 3 4 5 6 7 8ON KJ1 2 3 4 5 6 7 8ON KJa key switch KS1b ground control lidc CPU/display circuit board U22d Emergency Stop P1e DIP switch SW25Af DIP switch SW25models with manual outriggersmodels with hydraulic outriggers800-610-4101ActionRental.com