Version: 1.13 USA Modification Information 363 CONNECT THIRD PARTY OPTIONS4. Plug the supplied cable (E37-1075-x5) to the QE-2board.5. Cut out the adhesive cushion tape for the TK-7180/8180 transceivers.No. 4008 (3M) tape is used for the TK-7180/8180transceiver. No cushion tape is required for the TK-2180/3180 transceivers.6. Cut out the tape as same size of the SC20-460 PCB.Cut out the tape as 110 mm x 25 mm for the TK-7180/8180 transceivers.Note: The size may varies depending on the size of the boardand installation conditions.7. Attach the cushion tape and the adhesive tapesupplied with the QE-2 to the QE-2 board.• Stick the cushion to both sides of the TK-2180/3180 transceivers.• Wrap and shape the board with the cushion tapeas shown in the figure.8. Cut the cable in order to solder easily.• Cut the cable for approximately 10 mm to 40 mmwhen using the TK-2180/ 3180 transceivers. Refernext table, which is shown a sample length foreach wire.• Cut the cable for approximately 40 mm when usingthe TK-7180/ 8180 transceivers.3.2.2 Install QE-2 to TK-2180/ 31801. Remove two screws that hold the cover.2. Insert the tweezer into the cover screw hole and pullout the cover.3. Solder the TX-RX PCB (X57-6930-x0) to the wiresfrom the QE-2 board.You must connect the terminals as shown in thefollowing table.Figure 3-3 Connecting with QE-2 (TK-2180/ 3180)110 mm25 mmAdhesive tapeQE-2 Lengthmm Color TK-2180/ 3180Terminal nameOPT5Man Down 20 Blue OPT6A+ 40 Red OPT3OPT1CH BUSY 20 Vio RXDEmergency 20 Grn TXDAUX I/O 40 Gry RXIPTT 40 Yew STONKEY 25 Bwn TCNTTone Ctrl 40 W/Y TXORXEOAud Inhib 60 W OPT2Side Tone 40 Org OPT4Data Out 60 W/B GNDA- 60 Blk SB2RXEITXIRXO5ADI/AINH