Configuring Your Server 4-5Configuration ExamplesThe following describes examples of configuration required to use software-link features or forsystem operations.Time and Date SettingsYou can also change the time and date settings via the operating system commands.Select [Main] - [System Time].Select [Main] - [System Date].Link with Management SoftwareTo control power supply of the server with NEC ESMPRO Manager via the networkSelect [Advanced] - [Advanced Chipset Control] - [Wake On LAN/PME] - [Enabled].Select [Server] - [AC LINK] - [Stay Off].Hard Disk DriveTo check the hard disk drive statusSelect [Main] - [Primary IDE Master] and check the status indications.To configure the SW RAID (on-board) with SATA hard disk drivesSelect [Advanced] - [Peripheral Configuration] - [SATA Controller Mode Option] -[Enhanced]. Then select [Advanced] - [Peripheral Configuration] - [SATA RAID] -[Enabled], and configure the RAID drive.IMPORTANT: Be sure to set to [Enabled] after executing [LoadSetup Defaults] or CMOS clear. Leaving this parameter as the factory-set value (Disabled) may destroy the data in hard disk drive.UPSTo link power supply with the UPS To power on the server when power is supply from the UPSSelect [Server] - [AC LINK] - [Power On]. To keep the server off-powered even when power is supplied from the UPSSelect [Server] - [AC LINK] - [Stay Off]. To keep the server off-powered even when power is supplied from the UPS if the POWERswitch was used to power offSelect [Server] - [AC LINK] - [Last State].