Configuring Your Server 4-23Option Parameter Description Your SettingBoot Monitoring [Disabled]Every 5 minutesbetween 5 minutesand 60 minutesSpecify whether to enable ordisable the boot monitoringfunction on booting, or select thetime limit for timeout.To use this function, install NECESMPRO Agent. Set this item to"Disabled" if the system is bootedfrom OS without installation ofNEC ESMPRO Agent.Boot MonitoringPolicy[Retry 3 Times]Retry Service BootAlways ResetSpecify the processing at theoccurrence of timeout during bootmonitoring.If [Retry 3 times] is selected, thesystem is reset after theoccurrence of timeout and OS bootis retried up to three times.If [Retry Service Boot] is selected,the system is reset after theoccurrence of timeout and OS bootis retried up to three times. Thenthe boot is tried from the servicepartition for three times. The failurein the third boot causes the systemto stop booting.If [Always Reset] is selected, thesystem is reset after theoccurrence of timeout and OS bootis retried repeatedly.* If no service partition exists inthe system, OS boot is retriedrepeatedly from the systempartition.Thermal Sensor Disabled[Enabled]Specify whether to enable ordisable the thermal sensormonitoring function. If a thermalerror is detected with this itembeing set to "Enabled", the systemstops at the end of POST.BMC IRQ Disabled[IRQ 11]Set the IRQ for BMC.Post Error Pause Disabled[Enabled]Indicates whether POST is abortedonce at the end of POST if an erroroccurs during the execution ofPOST.AC-LINK Stay Off[Last State]Power OnSpecify the state of power whenthe AC power to the server isturned off once and then on. (Seethe table below.)