9-20 Upgrading Your ServerInstallationInstall a DIMM in the following procedure.IMPORTANT: The server supports DIMMs of only the low-profiletype (30 mm (1.2 inches) in height). It does not support DIMMsexceeding the specified height.1. See the section "Preparing for Installation and Removal" described earlier to prepare.2. Pull out the server from the rack.3. Open the logic cover.4. Push the DIMM straight into the socket.NOTE: Make sure of the orientation of the DIMM.Position the DIMM so that a notch in the bottom edge of the DIMMaligns with the keyed socket. Applying too much pressure can damagethe socket. Keyed DIMMs insert only one way.IMPORTANT: To avoid damage to the socket, do not applyexcessive force while pressing the DIMM.The levers automatically close when the DIMM is inserted into the socket.Key slotKey5. Install the components you removed in steps 1 to 3.6. Power on the server and verify that POST displays no error messages.If POST displays an error message, take a note on the message and see the POST errormessages listed in Chapter 8.7. Start the SETUP and select [Advanced] → [Memory Configuration] to verify that theinstalled DIMM shows the status "Normal". (See Chapter 4 or details.)8. Select "Yes" for [Reset Configuration Data] on the [Advanced] menu.This setting is required to change the hardware configuration data. See Chapter 4 fordetails.9. If the Windows operating system is in use, set the paging file size to the recommendedvalue (total memory size × 1.5) or a greater value. See Chapter 5 for details.