222 Chapter 4: Diagnosing faults553-3211-510 Standard 1.0 October 1998Lowest LCN for DTE/DCE This specifies the lowest X.25 virtualcircuit number that will be assigned for an incoming (if DTE) oroutgoing (if DCE) X.25 call request. It is not used by theApplication Module. The default value is -1.Highest LCN for DTE/DCE This specifies the highest X.25virtual circuit number that will be assigned for an incoming (ifDTE) or outgoing (if DCE) X.25 call request. It is not used by theApplication Module. The default value is -1.Lowest LCN This specifies the lowest X.25 virtual circuit numberthat will be assigned for an incoming/outgoing X.25 call request.The default value is 1.Highest LCN This specifies the highest X.25 virtual circuitnumber that will be assigned for an incoming/outgoing X.25 callrequest. The default value is 4095.LOC LIC This specifies the lowest X.25 virtual circuit numberthat will be assigned for an incoming (if DCE) or outgoing (ifDTE) X.25 call request. It is not used by the Application Module.The default value is -1.HOC HIC This specifies the highest X.25 virtual circuit numberthat will be assigned for an incoming (if DCE) or outgoing (ifDTE) X.25 call request. It is not used by the Application Module.The default value is -1.T10 This specifies (in 1/10 second increments) the amount oftime the application will wait for an X.25 Restart Confirmationpacket after sending an X.25 Restart packet to the host (T20 forDTE).T11 This specifies (in 1/10 second increments) the amount oftime the host will wait for an X.25 Call Accept packet fromMeridian Link after sending an X.25 Call Request packet (T21 forDTE).T12 This specifies (in 1/10 second increments) the amount oftime the application will wait for an X.25 Reset Confirmationpacket after sending an X.25 Reset Request packet to the host(T22 for DTE).