44871001TH Rev.6 4-52Oki Data CONFIDENTIAL4.REPLACEMENT OF PARTS4.2.25 Plate Side R Assy(1) Separate the Plate Side R Assy. (Refer to 4.2.23)(2) Remove two (or three) screws (Silver) . Remove the Guide-Cassette-R .(3) Remove two screws (Black) . Remove the Connector .(4) Remove four screws (Silver) . Remove the Plate-ID-Gear , Gear-Idle-Z21 ,Gear-Idle-Z30-33 .(5) Remove the screw (Silver) . Remove the Holder-Switch and Micro switch .(6) Remove two screws (Silver) , the screw (Black) . Remove the Guide-ID-Rand Motor-Fan (40×15) , Board-974 , Spring-ID Lock R .(7) Remove the screw (Silver) . Remove the Guide-Cable .(8) Installing is performed by the inverse procedure with removing.Note!1. Beware of not to touch the DC motor inattentively (Do not rotate motor).2. Install Motor-FAN (40×15) with the label side inward and with its notch fitted tothe appropriate projection of Guide-ID-R .3. While removing or installing FAN, do not press impeller of the FAN as shown bythe following photo. In case of the impeller unfastened by mistake, do not reuse itand install a new FAN.View AView AProjectionNotchImpeller