Oki Data CONFIDENTIAL44871001TH Rev.6 6-166. MAINTENANCE MENUS6.4.2 Ordinary self-diagnostic mode (level 1)Menu items of the ordinary self-diagnostic mode are shown below.Item Self-diagnosticmenu Adjustment contents Maintenanceutilities1 Switch scan test SWITCH SCAN Entry sensor check andswitch checkRefer to 5.3.1 No.212 Motor clutch test MOTOR&CLTCHTESTMotor and clutchoperation testRefer to 5.3.1 No.223 Test printexecutionTEST PRINT PU built-in test patternprintIt is not possible tooperate it.4Consumable itemcounter displayCONSUMABLESTATUSConsumable itemsconsumption statusdisplayRefer to 5.3.1 No.235Consumable itemaccumulativecounter displayPRINTER STATUS Consumable itemsaccumulativeconsumption statusdisplayRefer to 5.3.1 No.236Factory/Shippingmode selectionFACTORY MODESETSwitching between theFactory mode and theShipping modeRefer to 5.3.1 No.3,No.247 FUSE statuscheckRespective FUSEs statusdisplayRefer to 5.3.1 No.3,No.248Engine parametersettingSENSOR SETTING Valid/Invalid setups oferror detection by varioussensorsRefer to 5.3.1 No.259 LED Head serialnumber displayLED HEAD DATA LED Head serial numberdisplayIt is not possible tooperate it.10 NVRAMparameter settingNVRAMPARAMETERDo not use this item It is not possible tooperate it.6.4.2.1 Entering self-diagnostic mode (level 1)1. Make sure that the LCD is in standby state (no Error window is shown) andpress the [Setting] to move to the setting widow and then press the followingbutton in the indicated sequence.[#] → [0] → [1] → [0] → [3] → [ ]2. Type in the password to enter Service Maintenance Menu. It is [000000] bydefault. (Enter 0 six times)3. Select [Printer Maintenance] → [Engine Diag Mode] in the Service MaintenanceMenu and press the [6].6.4.2.2 Exiting self-diagnostic mode1. When the [4] is pressed from Diag Mode (Window displaying/Factory state), thesetting window will return.