98 DBS 576 (USA), issued January 1999 576-20-700Chapter 4. User Maintenance Section 700 - OperationSet Special Day ModeDescription(For a description of Automatic Day/Night System Mode, see “Automatic Day/Night Mode” on page42.)You can specify up to 20 special days for the System. For each special day, you can specify up to 5modes settings.OperationTo set the Special Day Modes:Action Result1. If not already in User Maintenance mode, enter User Main-tenance mode. (See “To enter User Maintenance mode:” onpage 79.)81-User MAINT displays2. At the 81 level, enter 07.3. Press the HOLD key. 8107-System Mode displays4. Enter 1.5. Press the HOLD key. 1-Mode Special Day displays6. Press the HOLD key. 1000 :MMDDSpecial Day 01 displays7. Enter the date by month (two characters) and day (two char-acters) for the Special Day 1.Note: To clear an entry or existing data, press the FLASHkey.8. Press the HOLD key. 1001 :HHMMS Day 01-1 Start displays9. Enter the start time in hours (two characters) and minutes(two characters) for mode 1.Note: To clear an entry or existing data, press the FLASHkey.10. Press the HOLD key. 1002 :S Day 01-1 Mode displays11. Enter the desired mode for Special Day ( (0 - None, 1 -Day 1, 2 - Day 2, 3 - Night, 4 - Night(1), 5 - Night (2)).Note: To clear an entry or existing data, press the FLASHkey.12. Press the HOLD key. Next Special Day mode displays13. To set additional Special Day modes, press the volume upor down key or press the HOLD key to move to the desiredmode.