1483-13 Error HistoryThe error history displays the dates, time, and details of the errors occurred in the past.“File” - “ERROR”The “Error History” dialog box is displayed.The dates, times, types, details, and error code of the error occurrence for the latest 255 times are displayed.Details of Error HistoryItem DescriptionSave as file The error history can be saved as file in the test format.Clear history Erases whole error history memorized in the head.Close Closes the “Error History” dialog box.Details of Error History CodeReleased interlock of the power supply box. E01Entered the laser radiation stop of the I/O connector. E02No marking file is existed. E04Released the interlock during marking. E10Entered laser radiation stop during marking. E11Occurred shutter operation during marking. E12Opened head cover. E20Occurred error on the galvanometer. E21, 22Occurred error on laser tube. E23Occurred error in marking file. E25Existed data out of the marking area. E26System error E30 to E39If the key switch is turned off during either excitation or laser radiation stop, the error related tothe galvano may be recorded.CHECK