401-4 Connecting Laser Marker1-4-1 Connecting Head and Power Supply BOXConnect the following items using the attached specific cables.• Connect the items above using the attached specific cables.• For the connectors location, refer to “1-2-1 Head” (P.34) and “1-2-2 Power Supply BOX” (P.35).• Attached AC power cable varies depending on each model. Please select a cable suitable forthe standards in the country or region where it is used.1. Perform the connection of the AC power at the end. Do not insert or pull cable with the powerin supplied state.2. Pay attention to the power source so as not to occur noise with enough.3. Set each connecting cable away from the device that generates high voltage, power line, andlarge switching surge as far as possible.4. If any noise is occurred on the power source, use the noise cut-off transducer.5. Be sure to ground the F.G. (frame ground) terminal. Refer to “1-2-2 Power Supply BOX” (P.35)for the terminal position.6. Fix the connector with screws securely so as not to drop it.7. To operate this laser marker, connect the following signals on I/O connector. For the details,refer to “4-1-2 I/O Connector” (P.157).• Connect the power supply to [IN COM.] (pin No.14) and to [OUT COM.] (pin No.15) respectively.• Connect [LASER STOP] (pin No.4) and [OUT COM.] (pin No.15) to release the erroneous irradiationprevention function for the laser.HeadPower Supply BOXHead Power Cable (5m) To POWERTo InletTo Interlock ConnectorTo Interlock System AC Power Cable (5m)Wiring of I/OCHECK