1885-1 TroubleshootingIf any operation errors occur, check items below first.When the problems cannot be resolved by following the below measures, please contact us.Troubles Possible Causes Measures Ref.PagePower supply is notturned on.Power cable is not connected. Connect the power cable. 40Power cable is not pluggedin outlet Insert the plug in the socket. 40The guide laser doesnot light.The shutter lever is not setto the guide laser side. Set the shutter lever to the guide laser side. 134Data cannot bemarked.The marking start commandis not input. Input the marking start command. -The distance to the workhas not been calibrated. Calibrate the distance to the work. 54Laser power and scanspeed are not appropriateto the marking targetobject.Raise the laser power or lower the scan speed. Orperform both of them. 126The trigger signal is keptON. Since the trigger signal sensitive to the edge, input theedge. 164The manual shutter isclosed (in remote mode). Open the manual shutter. 43The laser radiation stopinput of the I/O connectoris OFF.Turn ON the laser radiation stop input from the I/Oconnector. 13The interlock of the powersupply BOX is removed. Attach the optional interlock connector. 12