Chapter 5 Operations — Web control function166 - ENGLISH[E-mail set up] pageE-mail can be sent to preset E-mail addresses (up to two addresses) periodically or when an error or problem hasoccurred.Click [Detailed set up] → [E-mail set up].1234561 [ENABLE]Select [ENABLE] to use the E-mail function.2 [SMTP SERVER NAME]Enter the IP address or the server name of the E-mail server(SMTP). To enter the server name, the DNS server needs to beset up.3 [MAIL FROM]Enter the E-mail address of the projector. (Up to 63 charactersin single byte)4 [MEMO]Enter information such as the location of the projector thatnotifies the sender of the E-mail. (Up to 63 characters in singlebyte)5 [MINIMUM TIME]Change the minimum interval for the temperature warningE-mail. The default value is 60 minutes. In this case, anotherE-mail will not be sent for 60 minutes after sending thetemperature warning E-mail even if it reaches the warningtemperature.6 [INTAKE AIR TEMPERATURE]Change the temperature setting for the temperature warningmail. A temperature warning E-mail is sent when thetemperature exceeds this value.879877 [E‑MAIL ADDRESS 1], [E‑MAIL ADDRESS 2]Enter the E-mail address to be sent. Leave [E-MAIL ADDRESS2] blank when two E-mail addresses are not to be used.8 Settings of the conditions to send E-mailSelect the conditions to send E-mail.[MAIL CONTENTS]:Select either [NORMAL] or [SIMPLE].[ERROR]:Send an E-mail when an error occurred in the self-diagnosis.[INTAKE AIR TEMPERATURE]:Send an E-mail when the intake air temperature has reachedthe value set at the above field.[PERIODIC REPORT]:Place a check mark on this to send an E-mail periodically.A mail will be sent on the day and time with the check mark.9 [Submit]Update the settings.