3-10Connection and Wiring33.7 Wiring of Sensor Brake TerminalPin # Signal name1 COMP02 XORG3 XOTD4 XOTU5 (NC)6 XBRKP7 XBRKN10mm1) Push down the lever witha screwdriver.2) Insert the wire deeply. 3) Push up the lever(until you hear the click)Pin #7654SignalnameXBRKNXBRKP(NC)XOTU32XOTDXORG1COMP0The recommended sensor logic is B contact.Set the sensor to OFF when the light is shielded. The sensor described above will be set to OFF when the light is shieldedby the following result.Home position sensor(-) Over travel(+) Over travelDC powersupply123412341234+-Example of sensor connection (sensor: EE-SX670 manufactured by Omron)Rated voltageInput specifications12~24VDC (±10%)Rated inputcurrent4.1 mA/point (at 12 VDC)8.5 mA/point (at 24 VDC)Inputimpedance 3.0kΩOperating voltage(relative to COMP*)At OFF: 3.0 VDC or lessAt ON: 9.0 VDC or moreAllowableleakage currentOFF is guaranteed at 1.0mA or less.470Ω2.7kΩCOMP0XORGXOTDXOTU100kΩ10kΩ0.01μFVccPS2805[Electrical specifications]Electric wirespecification! 0.3 to 0.75 mm 2, electric wire coating with 10 mm of the coreexposed at the tip! If a twisted wire is used, the diameter of the strand should beφ 0.18 or larger.See the panel surface of the driver for the pin numbers. Made by Sato Parts (ML1900H)