Service and Repair Manual May 2020Deutz TCD 2.2 L3 Engine Fault Codes180 SX™-105 XC™ • SX™-125 XC™ Part No. 1271700GTDTC = Diagnostic Trouble CodeFMI = Failure Mode IdentifierSPN = Suspect Parameter NumberDTC SPN FMI Description1587 97 0 Water in fuel level prefilter;maximum value exceeded.188 523240 9 Timeout CAN message functionmode control.219 520253 2 Rolling counter fault CANmessage EAT control.220 4206 2 Fault check for Rolling Counterof TSC1AE.221 4206 2 Fault check for Rolling Counterof TSC1AR.222 4206 2 Fault check for Rolling Counterof TSC1TE.223 4206 2 Fault check for Rolling Counterof TSC1TR.349 3349 0 Timeout error of CAN receiveframe active TSC1AE.350 3349 0 Timeout error of CAN receiveframe passive TSC1AE.351 3349 0 Timeout error of CAN receiveframe active TSC1AR.352 3349 0 Timeout error of CAN receiveframe passive TSC1AR.353 3349 0 Timeout error of CAN receiveframe TSC1TE active.354 3349 0 TSC1 receive timeout error.Shout circuit to ground error.355 3349 0 Timeout error of CAN receiveframe TSC1TR.356 3349 0 Passive timeout error of CANreceive frame TSC1TR.361 3349 0 Timeout error of CAN receiveframe TSC1AE. TractionControl.363 3349 0 Timeout error of CAN receiveframe TSC1AR. Retarder.365 3349 0 Timeout error of CAN receiveframe TSC1TE. Setpoint.DTC SPN FMI Description367 3349 0 Timeout error of CAN receiveframe TSC1TR; control signal.38 1485 3 ECM main relay voltage abovenormal or shorted to high.39 1485 3 ECM main relay voltage abovenormal or shorted to high ofactuator relay 2.40 1485 3 ECM main relay voltage abovenormal or shorted to high ofactuator relay 3.41 1485 4 ECM main relay voltage belownormal or shorted to low.42 1485 4 ECM main relay voltage belownormal or shorted to low ofactuator relay 2.43 1485 4 ECM main relay voltage belownormal or shorted to low ofactuator relay 3.48 168 0 Battery voltage above normaloperational range.49 168 1 Battery voltage low normaloperational range.50 168 3 Battery voltage above normal orshorted to high.51 168 4 Battery voltage above normal orshorted to low.516 523982 0 Power stage diagnosis disabled.High battery voltage.517 523982 1 Power stage diagnosis disabled.Low battery voltage.52 168 0 High battery voltage.Warningthreshold is exceeded.567 27 5 Engine exhaust gas recirculation1 valve position voltage abovenormal or open circuit.570 27 3 Engine exhaust gas recirculation1 valve position voltage abovenormal or shorted to battery 1.571 27 3 Engine exhaust gas recirculation1 valve position voltage abovenormal or shorted to battery 2.