Error Messages and Codes 3-79Non-Phaser 6250 Imaging UnitCode 95: CRUM I.D. error. A non-Phaser 6250 Imaging Unit has been detected inthe printer.8 Check continuity between J144 <=> J140of Harness assembly EEPROM. Refer towiring diagram "Laser Unit" onpage 10-22.Replace the EngineControl Board,page 8-107.ReplaceAssembly,HarnessEEPROMPL 13.1.10.Troubleshooting Reference TableApplicable Parts Wiring and Plug/Jack Map ReferencesImaging Unit PL 9.1.3 "Xerographics 2" on page 10-24"Laser Unit" on page 10-22Troubleshooting Procedure TableSteps Actions and Questions Yes No1 Check the part number listed on theImaging Unit. Is it a genuine XeroxPhaser 6250 part?Go to Step 2. Replace theImaging Unit.2 Remove and reinstall the Imaging Unit.Does the error recur?Go to Step 3. Complete3 Remove the Imaging Unit and check forbroken or bent pins on the connector.Replace theImaging Unit,page 8-4.Go to Step 4.4 Does the error recur after the ImagingUnit is replaced with a new one?Go to Step 5. Complete5 Is the Imaging Unit connector P/J710 onthe Plate Assembly Dispenser, PL10.1.13, damaged?Replace the PlateAssemblyDispenser,page 8-77.Go to Step 6.6 Check the connection of the CRUMHarness, PL 10.1.12, to the connectorblock. Is the harness properly connected?Go to Step 7. Reconnect theharness.Troubleshooting Procedure TableSteps Actions and Questions Yes Nomanuals4you.commanuals4you.com