5.3 Monitoring Machine Operation5.3.4 XY Trace5-695 Debugging Programs Trace Execution Toolbar Trace Data SettingsUse this button to select the axes and the trace targets. Sampling and Trigger SettingsThis dialog box is used to set the trace name, the sampling settings, and the trigger settingparameters.Refer to the following section for details on sampling and trigger settings.Realtime Tracing− Sampling and Trigger Settings on page 5-47 Starting and Stopping TracesNo. Item Description X-Y Axis Specification Use these boxes to specify the X and Y axes. Trace TargetUse these check boxes to specify the trace targets. You can select thefollowing two motion parameters:ILxx10: Machine Coordinate System Calculated Position (ILxx10)ILxx16: Machine Coordinate System Feedback Position (ILxx16) OK The OK Button sets the X-Y axes and the trace targets, and enables theSampling & Trigger Setting Button. Cancel The Cancel Button returns you to the XY Trace Dialog Box without set-ting the X-Y axes and the trace targets.Function DescriptionStart Trace Use this button to start the trace. The data that is sampled will be displayed in real-time.Real Time DisplaySelect the Real Time Display Check Box to display the axes moving in realtime.If more than one Trace Tab Page is open, you can use a realtime display for only oneof them.Stop Trace Use this button to stop the trace. When the trace stops, all trace buffer data will becollected and displayed.Click the Trace Data Setting Button to display the following dialog box: