YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual 2175.6 Operator Programming ErrorsTroubleshooting55.6 Operator Programming ErrorsAn Operator Programming Error (oPE) occurs when an inappropriate parameter is set or anindividual parameter setting is inappropriate. The drive will not operate until the parameteris set correctly; however, no alarm or fault outputs will occur. If an oPE occurs, investigatethe cause and refer to Table 5.10 for the appropriate action. When oPE error is displayed,press the ENTER button to display U1-34 (oPE fault constant). This monitor displays theparameter causing the oPE error.◆ oPE Codes, Causes, and Possible SolutionsTable 5.10 oPE Codes, Causes, and Possible SolutionsLED Operator Display Error NameoPE01 Drive Capacity Setting FaultDrive capacity and then value set to o2-04 do not match.Cause Possible SolutionsThe drive capacity setting(o2-04) and the actual capacity of the drive are not thesame.Correct the value set to o2-04.LED Operator Display Error NameoPE02Parameter Range Setting ErrorUse U1-18 to find which parameters were set outside thesetting range.Cause Possible SolutionsParameters were set outside the possible setting range. Set parameters to the proper values.Note: Other errors are given precedence over oPE02 when multiple errors occur at the same time.LED Operator Display Error NameoPE03Multi-Function Input Selection ErrorA contradictory setting is assigned to multi-functioncontact inputs H1-01 through to H1-07.Cause Possible Solutions• The same function is assigned to two multi-functioninputs.• Excludes “Not used” and “External Fault.”• Ensure all multi-function inputs are assigned to differentfunctions.• Re-enter the multi-function settings to ensure this doesnot occur.The Up command was set but the Down command wasnot, or vice versa (settings 10 vs. 11). Correctly set functions that need to be enabled incombination with other functions.The Up 2 command was set but the Down 2 commandwas not, or vice versa (settings 75 vs. 76).