B.2 Parameter TableYASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual 371Parameter ListB◆ T: Motor TuningEnter data into the following parameters to tune the motor and drive for optimalperformancer1-38 DWEZ ConnectionParameter 19 (lower) Parameter 19 for connecting DWEZ (lower). 0000 toFFFF(H) 0 A A A 1865 —r1-39 DWEZ ConnectionParameter 20 (upper) Parameter 20 for connecting DWEZ (upper). 0000 toFFFF(H) 0 A A A 1866 —r1-40 DWEZ ConnectionParameter 20 (lower) Parameter 20 for connecting DWEZ (lower). 0000 toFFFF(H) 0 A A A 1867 —No. Name Description Range Def.ControlModeAddr.HexPg.V/fOLVPMT1-00 MotorSelection 1/2Selects which set of motor parameters are used andset during Auto-Tuning. If Motor 2 selection(H1- = 16) is not selected, this parameter willnot be displayed.1: 1st Motor - E1 to E22: 2nd Motor - E3 to E4 (this selection is notdisplayed if motor 2 has not been selected)1, 2 1 A A − 700 —T1-01 Auto-TuningMode SelectionSelects the Auto-Tuning mode.0: Rotational Auto-Tuning2: Stationary Auto-Tuning, Terminal resistanceonly,3: Rotational Auto-Tuning for V/f control(necessary for Energy Savings and SpeedEstimation type speed search)0, 2, 3<54>2 or 3in V/f0 or 2in OLV2 forMotor2A A − 701 —T1-02 Motor RatedPowerSets the motor rated power in kilowatts (kW).Note: If motor power is given in horsepower,power in kW can be calculated using the followingformula: kW = HP x 0.746.0.00 to650.000.40kW A A − 702 —T1-03<24>Motor RatedVoltage Sets the motor rated voltage in volts (V). 0.0 to255.5200.0V A A − 703 —No. Name Description Range Def.ControlModeAddr.HexPg.V/fOLVPM