Qlogic 3200 Series manuals
3200 Series
Table of contents
- document revision history
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- intended audience
- technical support
- Hardware Requirements
- Software Requirements
- Downloading QConvergeConsole CLI
- Installing QConvergeConsole CLI
- Standard Windows Interactive (CLI) Installation
- Passive Windows Installation
- Uninstalling QConvergeConsole CLI in a Windows Environment
- Uninstalling QConvergeConsole CLI in a Linux Environment
- Using Noninteractive Mode
- Starting QConvergeConsole CLI in Windows
- Main Menu
- Getting Help
- Command Format
- Command Summary
- extloopback
- configure test parameters
- ping target
- svmtool
- teamnew_portspreview
- testflash
- updimages_viewver
- vlanadd_preview
- vlandel_preview
- vtcfgview
- host configuration
- Host Configuration
- Command Variables
- DCE Statistics Parameters
- Driver Settings Parameters
- Adapter Statistics Parameters
- Run a Read/Write Buffer Test
- Run Adapter Diagnostics Read-write Buffer Test
- Data Pattern (DP) Test Patterns
- Link Status Parameters
- Adapter Parameters
- Noninteractive Command Variables
- CHAP Parameters
- Adapter Port Information
- model
- sdmrc
- stathba
- Adapter Information
- CNA Adapter Information (-icna)
- CNA VPD Information (-i)
- Adapter Configuration
- NIC Port Setting Configuration
- Display Configured Port Settings (-iset)
- Change Port Alias Name (-n)
- Flash Update (-updimages)
- Register Test (-testregister)
- Interrupt Test (-testinterrupt)
- Beacon/LED Test (-testled)
- Display NIC Port Statistics (-statport)
- Undo Reset NIC Statistics (-sunreset)
- Help (-h)
- FC Adapter Information (-i)
- FC Port Information (-i)
- FC VPD Information (-i)
- HBA Parameters
- Display HBA Parameters (-c)
- Configure HBA Parameters (-n)
- Restore Defaults
- Display Configuration
- Unbind Target(s)
- Boot Devices Configuration
- Display Boot Device(s) (-e)
- Configure Boot Device(s) (-e)
- Target Link Speed (iiDMA)
- Basic Configuration
- Export (Save) Configuration
- Save Flash (-b)
- Adapter Updates
- Parameters Update (-r)
- Adapter Diagnostics
- Loopback Test (-kl)
- Display Test Parameters
- Start Diagnostics Test
- Display Test Parameters (-kr)
- Start Diagnostics Test (-kr)
- Details (-dm)
- Adapter Statistics
- Display Parameters (-gs)
- Display HBA Statistics (-gs)
- Display Parameters
- Display Link Statistics (-ls)
- Exit
- CNA Adapter Information
- FCoE
- CNA Port Information
- iSCSI
- CNA VLAN Information
- Teaming Information
- data center bridging
- dce statistics
- CNA iSCSI Information
- CNA FCoE Configuration
- Target Persistent Binding
- Virtual Ports (NPIV)
- Driver Parameters
- Selective LUNs
- display lun configuration
- auto configure luns
- Generate Reports
- CNA iSCSI Configuration
- Port Configuration
- Port IP Settings
- Target Configuration
- CNA NIC Configuration
- Adapter Alias
- VLAN Configuration
- Team Configuration
- Flash Update
- Parameters Update
- Register Test
- Hardware Test
- Interrupt Test
- Link Test
- Default Loopback Test Parameter Values
- Read Write Buffer Test
- Default Read Write Buffer Test Parameter Values
- Beacon/LED Test
- Transceiver Diagnostics Monitoring Interface (DMI)
- Details
- iSCSI Adapter Diagnostics
- iSCSI Port Diagnostics
- Ping Target
- iSCSI Port Logs
- Display ARP Table
- Export Connection Error Log
- Display NIC Port Statistics
- Reset NIC Statistics
- Display Test Parameters (-gs)
- Reset Test Parameters
- Display FCoE Port Link Status
- Configure Test Parameters (-ls)
- Display iSCSI Port Statistics
- Reset iSCSI Statistics
3200 Series
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- intended audience
- documentation conventions
- technical support
- contact information
- Hardware Requirements
- Software Requirements
- Supported QLogic Adapters
- Downloading QConvergeConsole CLI
- Installing QConvergeConsole CLI
- Quiet or Silent Windows Installation
- Installation using Package Files (Solaris 10 or 11)
- Installation using p5p Files (Solaris 11 only)
- Uninstalling QConvergeConsole CLI
- Uninstalling QConvergeConsole CLI in a Linux Environment
- Uninstalling a p5p Installation (Solaris 11 only)
- Using Noninteractive Mode
- Using Interactive Mode
- Starting QConvergeConsole CLI in Solaris
- Getting Help
- Viewing General Help
- Viewing All Inventory
- Viewing All Flash Image Versions
- Viewing All Matching Flash Image Versions
- Viewing All Flash Updates
- Command Format
- Command Summary
- extloopback
- h (Help)
- icna (CNA Adapter)
- intloopback
- link
- nh (Adapter Alias [NIC Configuration])
- ping
- statport (Display NIC Port Statistics)
- sunreset (Undo Reset NIC Statistics)
- team_allowCNAsIn8023adTeam (LACP Override)
- teamlist (Display Teams List)
- teamnew_portspreview
- testflash
- testlink (Link Test)
- v, -ver (Display Program Version Information)
- vlanadd_preview
- vlaninfo (Display VLAN Information)
- vtrestore (Restore VLAN & Teaming Configuration)
- vtsave (Save VLAN & Teaming Configuration)
- Displaying System Information (Command Line Options -g, -z, and -tp)
- Host Configuration (Command Line Option -z)
- Host Port Configuration
- Command Variables
- b (Flash Update; Save Flash)
- c (Display HBA Parameters)
- DCE Statistics Parameters
- dm (Transceiver Diagnostics Monitoring Interface [DMI])
- fs (Driver Parameters)
- fwdump (Firmware Dump)
- ha (Adapter Alias [FCoE Configuration])
- kl (Loopback Test)
- kr (Read Write Buffer Test)
- Running a Read/Write Buffer Test
- Running an Adapter Diagnostics Read/write Buffer Test
- Diagnostics Parameters
- l (FC Target/LUN Information)
- ls (Display Parameters [HBA Statistics])
- m (Selective LUNs)
- n (Configure HBA Parameters)
- Adapter Parameters
- p (Target Persistent Bindings)
- pa (Adapter Port Alias [FCoE Configuration])
- pc (Adapter Personality Change)
- q (Target Link Speed [iiDMA])
- r (Parameters Update; Save HBA Parameters)
- t (FC Target/LUN Information)
- trace
- vp (Virtual Ports [NPIV])
- z (All Information)
- addchap (Add a CHAP Entry)
- c (CNA Port Information—iSCSI)
- d (Drivers Update)
- dr (Display Default Router List [IPv6])
- dspchap (Display CHAP Table)
- dtlia (Login and Persist a Discovered Target)
- CHAP Parameters
- import (Import HBA Configuration)
- ipdhcp (Configure IP Settings)
- lcd (Display Configured Link Configuration)
- n (Configure iSCSI Settings)
- nc (Display Neighbor Cache [IPv6])
- netconf6 (Configure IPv6 Settings)
- nh (Configure iSCSI Settings)
- pdt (Disable a Target)
- rdh (Port Restore Factory Defaults)
- rwt (Read Write Buffer Test—iSCSI)
- save (Save Host Configuration)
- statport (Display iSCSI Port Statistics)
- strd (Mark Send Target for re-discovery)
- vpd (CNA VPD Information—iSCSI)
- eswitchinfo
- finfo
- peswitchcfg
- setmaxbw (Modify Maximum Bandwidth)
- Adapter Information
- CNA Port Information (-pinfo)
- CNA VPD Information (-vpd)
- Adapter Configuration
- NIC Port Setting Configuration (-c)
- Display Configured Port Settings (-iset)
- Change MAC Alias Name (-n)
- Flash Update (-updimages)
- Register Test (-testregister)
- Interrupt Test (-testinterrupt)
- Beacon/LED Test (-testled)
- Adapter Statistics
- Reset NIC Statistics (-sreset)
- Refresh
- FC Port Information
- FC VPD Information (-i)
- FC Target/LUN Information (-t)
- Adapter Alias (-ha)
- Adapter Port Alias (-pa)
- Display HBA Parameters (-c)
- Configure HBA Parameters (-n)
- Restore Defaults
- Target Persistent Binding (-p)
- Display Configuration
- Unbind Target(s)
- Boot Devices Configuration
- Display Boot Device(s) (-e)
- Configure Boot Device(s) (-e)
- Virtual Ports (NPIV) (-vp)
- Target Link Speed (iiDMA) (-q)
- Basic Configuration
- Driver Parameters (-fs)
- Selective LUNs (-m)
- Display LUN Configuration
- Manual Configure LUNs
- Quality of Service (QoS)
- Export (Save) Configuration
- Generate Reports (-g)
- Adapter Updates
- Driver Update (-d)
- Parameters Update (-r)
- Firmware Preload Table Update (-u)
- Fibre Channel Dump (-fwdump)
- Loopback Test (-kl)
- Display Test Parameters
- Start Diagnostics Test
- Read Write Buffer Test (-kr)
- Reset Test Parameters
- Transceiver Diagnostics Monitoring Interface (DMI)
- Details (-dm)
- Display Parameters (-gs)
- Display HBA Statistics (-gs)
- Display Parameters
- Configure Parameters (-ls)
- Help (-h)
- CNA Adapter Information
- FCoE
- CNA Port Information
- iSCSI (-c; -pinfo)
- CNA VPD Information
- CNA VLAN Information
- CNA FCoE Information (-cna)
- CNA iSCSI Information
- CNA Port Target/LUN Information
- HBA Parameters
- Target Persistent Binding
- Virtual Ports (NPIV)
- Target Link Speed (iiDMA)
- Driver Parameters
- Selective LUNs
- Generate Reports
- Personality
- CNA iSCSI Configuration
- Port Configuration
- Port IP Settings
- Target Configuration
- CNA NIC Configuration
- NIC Port Setting Configuration
- VLAN Configuration
- Team Configuration
- Flash Update
- Drivers Update (-d)
- Firmware Serdes Table Update (-sp)
- Register Test
- Hardware Test
- Interrupt Test
- Link Test
- Default Loopback Test Parameter Values
- iSCSI
- Read Write Buffer Test
- Values
- iSCSI (-rwt)
- Beacon/LED Test
- General
- Details
- iSCSI Adapter Diagnostics (-dumpnvram)
- iSCSI Port Diagnostics
- Perform Read/Write Buffer Test
- Display ARP Table (-arp)
- Display Connection Error Log (-dce)
- Display Neighbor Cache (IPv6) (-nc)
- Reset NIC Statistics
- Undo Reset NIC Statistics
- Display Test Parameters (-gs)
- Display FCoE Port Link Status
- Display Link Statistics (-ls)
- Display iSCSI Port Statistics (-stat)
- Reset iSCSI Statistics
- NIC Partitioning (NPAR) Information
- NPAR Port Information (-pinfo)
- NIC Partitioning (NPAR) Configuration
- Bandwidth Configuration
- Modify Maximum Bandwidth (-setmaxbw)
- ESwitch Configuration
- General ESwitch Statistics (-eswitchstats)
- View All ESwitch Statistics (-eswitchvportstats)
- Function x ESwitch Statistics
- Setting Up NIC Partitions
- Selecting Option 6 to View NPAR Information Options
- Viewing NPAR Configuration
- Selecting to Modify Minimum Bandwidth
- Setting Bandwidth Changes to Persist
- Selecting Function Type on Linux System
- What Is NPAR?
- QLogic Adapters That Support NPAR
- Function Type Changes
- Quality of Service
- eSwitch
- NPAR Setup
- NPAR Configuration Parameters and Setup Tools
- Interoperation of Bandwidth Settings for DCBX and NPAR
3200 Series
Table of contents
- document revision history
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- intended audience
- technical support
- contact information
- legal notices
- product safety compliance
- quick start
- additional resources
- What is a Converged Network Adapter
- Supported Operating Systems
- Environmental Specifications
- Converged Network Adapter SuperInstaller Installation
- Converged Network Adapter Function Configuration Package Contents
- QLflash Command Line Options
- Adapter Configuration (CNA/IEA Function Configuration Utility)
- Function
- Type
- Exit the CNA Function Configuration Utility
- Introduction
- Requirements
- vCenter Server
- Subsequent Update Installation
- Removing the QLogic Adapter CIM Provider
- Starting the QLogic Adapter vCenter Plug-in
- Installing the Flash Utility
- Using the vCenter Plug-in on a Tomcat Server
- Installing Tomcat on Linux
- Starting and Stopping Tomcat on Windows
- Launching the Plug-in from vSphere Client
- Installing NIC in Linux
- Packaging Content
- Configuring PXE Boot
- QLogic 8200 CNA Function Configuration
- BIOS: Boot Settings
- Configuring Driver Software Parameters
- qaucli Utility
- phantomcore Utility
- Windows Driver Configurable Parameters
- Configuring NIC Driver Parameters with QCC GUI
- Team MAC Address
- Using the CLI for Teaming
- Teaming Configuration
- Creating a Team
- Creating a Failsafe Team
- Creating a Switch-Independent Load Balancing Team
- Creating an 802.3ad Static Team
- Creating an 802.3ad Dynamic Team
- Modifying a Team
- Adding a Team
- Modifying Advanced Team Properties
- Modifying Team Properties
- Modifying Failsafe Team Properties
- Deleting a Team
- Saving and Restoring Teaming Configuration
- NIC Partition (NPAR)
- Using NPAR under ESX
- Configuring NPAR in the BIOS
- vCenter Plug-in QLogic Adapter Tab Default View
- Series Configuration Range With NPAR
- Enabling a Physical Function
- NPAR Personality Changes
- Enabling NPAR
- eSwitch
- NIC TroubleShooting/Diagnostics
- Windows Property Page Diagnostics
- Diagnostics Tests on Windows
- Windows QConvergeConsole CLI—Getting Help
- Running Windows Diagnostic Tests in the CLI
- Windows Diagnostic Test Descriptions
- Windows Diagnostic Test Messages
- NIC Troubleshooting Guidelines
- NIC Troubleshooting Diagram 2
- iSCSI Overview
- Installing iSCSI in ESX
- iSCSI Configuration
- Configuring an iSCSI Initiator in Windows
- Configuring an iSCSI Initiator in VMware
- Accessing Fast!UTIL
- iBFT Boot Setup
- iSCSI TroubleShooting
- iSCSI Troubleshooting Diagram
- Installing FCoE
- Firmware Installation
- HBA Parameters
- Configuring Boot Devices with the BIOS
- Configuring Selective LUNS with the Interactive QCC CLI
- FCoE Troubleshooting Diagram
- adapter leds
3200 Series
Table of contents
- What is a Converged Network Adapter
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- intended audience
- technical support
- contact information
- legal notices
- product safety compliance
- quick start
- additional resources
- What is an Intelligent Ethernet Adapter
- Supported Operating Systems
- Environmental Specifications
- Converged Network Adapter SuperInstaller Installation
- Contents
- QLflash Command Line Options
- Adapter Configuration Utility
- Type
- Installing the QLogic Adapter vCenter Plug-in for ESX/ESXi
- Requirements
- Installing the QLogic Adapter CIM Provider
- Subsequent Update Installation
- Starting the QLogic Adapter vCenter Plug-in
- Updating the Flash
- Using the vCenter Plug-in on a Tomcat Server
- Starting and Stopping Tomcat on Linux
- Installing the vCenter Plug-in on Tomcat
- Launching the Plug-in from vSphere Client
- Installing NIC in Linux
- Packaging Content
- Configuring PXE Boot
- QLogic 8200 CNA Function Configuration
- BIOS: Boot Settings
- Configuring Driver Software Parameters
- qaucli Utility
- QLogic Device Windows Property Pages
- Configuring NIC Driver Parameters with QCC GUI
- Configuring NIC Driver Parameters with QCC Interactive CLI
- Team MAC Address
- Using the CLI for Teaming
- Teaming Configuration
- Creating a Team
- Creating a Failsafe Team
- Creating a Switch-Independent Load Balancing Team
- Creating an 802.3ad Static Team
- Creating an 802.3ad Dynamic Team
- Modifying a Team
- Adding a Team
- Modifying Advanced Team Properties
- Modifying Team Properties
- Modifying Failsafe Team Properties
- Deleting a Team
- Saving and Restoring Teaming Configuration
- Using LACP on 8200 Series Adapters for Windows
- LACP Configuration with One vPC
- Invalid LACP Configuration (One vPC Linked to Two Nexus 5x00s)
- NIC Partitioning (NPAR)
- Setup Requirements
- NPAR Configuration
- Personality Changes
- Quality of Service
- eSwitch
- Configuration Management Tools
- NPAR Setup and Management Options
- QLogic OptionROM at POST
- Function Configuration Screen
- Selecting NIC Function Type to Change
- Selecting FCoE Function Type to Change
- QConvergeConsole (QCC) GUI
- NIC Partitioning Configuration Page
- NIC Partitioning—General Management Page
- QConvergeConsole (QCC) CLI
- Selecting Option 6 to View NPAR Information Options
- NPAR Configuration Selection Screen
- Selecting to Modify Minimum Bandwidth
- Setting Bandwidth Changes to Persist
- QLogic Device Windows Properties Page
- Selecting Properties from the Context Menu
- Enabling Partition
- Partition Enabled
- Selecting Convert to NIC from Context Menu
- Selecting Configure Function for Function 0
- Entering New Bandwidth Values
- NIC Partition Management Property Sheet
- NPAR Setup
- Default Settings
- NPAR Configuration Parameters and Setup Tools
- Frequently Asked Questions about NPAR
- Networking
- QLogic Device Windows Property Page Diagnostics
- Diagnostics Tests on Windows
- Windows QConvergeConsole CLI—Getting Help
- Windows Diagnostic Test Descriptions
- hardware test
- Windows Diagnostic Test Messages
- NIC Troubleshooting Guidelines
- NIC Troubleshooting Diagram 2
- iSCSI Overview
- Installing iSCSI in ESX
- iSCSI Configuration
- Configuring an iSCSI Initiator in Windows
- Configuring an iSCSI Initiator in VMware
- Accessing Fast!UTIL
- DHCP Boot Setup for iSCSI Boot (IPv4)
- iSCSI Boot Setup Using QCC GUI
- iSCSI Troubleshooting Diagram
- Installing FCoE
- Firmware Installation
- QLogic Adapter Parameters
- Configuring Boot Devices with the BIOS
- Configuring Selective LUNS with the Non-Interactive QCC CLI
- FCoE Troubleshooting Diagram
- adapter leds
manualsdatabase
Your AI-powered manual search engine