358 Parameters43.11 Brake resistor faultlimitSelects the fault limit for the brake resistor temperatureprotection function. When the limit is exceeded, the drivetrips on fault 7183 BR excess temperature.The value is given in percent of the temperature the resistorreaches when loaded with the power defined by parameter43.09 Brake resistor Pmax cont.105%0 … 150% Brake resistor temperature fault limit. 1 = 1%43.12 Brake resistorwarning limitSelects the warning limit for the brake resistor temperatureprotection function. When the limit is exceeded, the drivegenerates a A793 BR excess temperature warning.The value is given in percent of the temperature the resistorreaches when loaded with the power defined by parameter43.09 Brake resistor Pmax cont.95%0 … 150% Brake resistor temperature warning limit. 1 = 1%4444 Mechanical brakecontrolConfiguration of mechanical brake control.See also section Mechanical brake control (page 110).44.01 Brake control status Displays the mechanical brake control status word.This parameter is read-only.-0000h…FFFFh Mechanical brake control status word. 1 = 144.02 Brake torquememoryDisplays the torque (in percent) at the instant of the previousbrake close command.This value can be used as a reference for the brake opentorque. See parameters 44.09 Brake open torque sourceand 44.10 Brake open torque.--1600.0 … 1600.0% Torque at brake closure. See par.46.0344.03 Brake open torquereferenceDisplays the currently active brake open torque. Seeparameters 44.09 Brake open torque source and 44.10Brake open torque.This parameter is read-only.--1600.0 … 1600.0% Currently active brake open torque. See par.46.03No. Name/Value Description Def/FbEq16Bit Name Information0 Open command Close/open command to brake actuator (0 = close, 1 = open).Connect this bit to desired output.1 Opening torquerequest1 = Opening torque requested from drive logic2 Hold stoppedrequest1 = Hold requested from drive logic3 Ramp to stopped 1 = Ramping down to zero speed requested from drive logic4 Enabled 1 = Brake control is enabled5 Closed 1 = Brake control logic in BRAKE CLOSED state6 Opening 1 = Brake control logic in BRAKE OPENING state7 Open 1 = Brake control logic in BRAKE OPEN state8 Closing 1 = Brake control logic in BRAKE CLOSING state9…15 Reserved