Parameters 4197475 Winder speedsettingsRamping time adjustments and winder-related speedreference adaptation setup.See section Line speed on page 48.75.01 Max line speed Defines the maximum linear speed the production line isintended to run at.700.0 m/min0.0…32767.0 m/minMaximum speed of the machinery. 10 = 1 m/min75.02 Line speedreference srcSelects the source for the line speed reference. The targetline speed reference is defined as:75.51 Line reference In = (75.02 Line speed reference src/75.03 Line reference scaling) * 75.01 Max line speedAI1_SCALEDNULL Zero. 0AI1_SCALED 12.12 AI1 scaled value (see page 197). 1AI2_SCALED 12.22 AI2 scaled value (see page 198). 2FBA Reference 1 03.05 FB A reference 1 (see page 160). 3FBA Reference 2 03.06 FB A reference 2 (see page 160). 4M/F or D2DReference 103.13 M/F or D2D ref1 (see page 160). 5M/F or D2DReference 203.14 M/F or D2D ref2 (see page 161). 6MotorPotentiometer RefMotor potentiometer reference. See parameter 22.80 Motorpotentiometer ref act on page 256.7Other Source selection (see Terms and abbreviations on page152).-75.03 Line referencescalingDefines the custom scaling factor for line speed reference.For example, if line speed reference from the fieldbus isscaled from 0 to ± 20000 (INT), then set this value to 200.00(REAL).Note: Reference scaling can be set to 0, then input fromparameter 75.02 is interpreted directly as m/min (or ft/min)without any scaling.200.000.00…32767.00 Scaling factor. 100 = 1No. Name/Value Description Def/FbEq16