Synchronous Port Configuration4-5CSX WAN ConfigurationQuitCloses the WAN Configuration window.Synchronous Port ConfigurationThe WPIM-SY supports one physical serial interface on the CSX202 and theCSX400. Through the WAN Configuration window you can view the physicalconfiguration of your synchronous port and change the In Speed, Out Speed, andPort Type displayed for your synchronous connection. The WAN Configurationwindow for the WPIM-SY is shown in Figure 4-2 on page 4-4.In this window you will see the following fields:Line StatusDisplays the status of the port. The status can be one of the following:• Inactive — The connection through this port is not active.• OK — The port is the active port and the connection is operational.• In Alarm — The port is the active port, but the connection has experienced afailure. When either the Cts (Clear to Send) or Dsr (Data Set Ready) signal isOff and the signal is enabled, the port will enter the state of In Alarm.The left side of this portion of the window is color-coded to indicate the linestatus: Blue for Inactive; Green for OK; and Red for In Alarm.Port 1Displays the port type: Synchronous.In SpeedAllows you to enter the speed of input communications of the synchronous port.Out SpeedAllows you to enter the speed of output communications of the synchronous port.Port TypeIndicates the type of connection used at the port. The available connections areRS422, RS232, V.35, or None. You should set the port type to match theconfiguration of the connected equipment.Cts EnableThis field displays whether the Cts (Clear to Send) signal is enabled. If the Ctssignal is enabled (Yes), the device will use it to determine the status of theconnection. If the signal is disabled (No), it will be ignored.