4) Turn the magnet roller clockwise (viewing from the front).5) When a full coating has developed in the area from which toner was removed in step3), repeat steps 3) through 5).N. Separation Claw/Separation Claw Drive Assembly1. Removing from the Drum Unit1) Remove the process unit from the copier. (See p. 7-18.)1. Take care not to bend the separation claw.2. Take care not to damage the photosensitive drum.2) Remove the screw q, and remove the No. 2 insulating plate w.3) Remove the screw e, and remove the claw holder r.Figure 4-356e erqwCOPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)CHAPTER 4 IMAGE FORMATION SYSTEM4-71Caution:Download service manual and resetter printer at http://printer1.blogspot.com