B. Exposure System1. Adjusting the Scanner Home PositionAfter making copies, remove the control panel, and check to make sure that the linein section A on the electrode mount (front) of the No. 1 mirror mount is in section B ofthe hole of the glass support (front).Otherwise, change the setting of ‘BRAKE_SC’ in service mode ( ) so that theline in section A is within section B.Figure 11-208BNo. 1 mirror mountElectrode (front)Section A of left of wallGlass support(front)Hole]3]COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)CHAPTER 11 TROUBLESHOOTING11-11Download service manual and resetter printer at http://printer1.blogspot.com