---------------------------------------------------------------0 0 up up 7943 up 7992 up 7975 up 80080 1 up up 7975 up 8008 up 7992 up 79750 2 up up 7959 up 7959 up 7959 up 7975Speed in RPMThe following example runs offline diagnostics on a standalone switchDell#diag systemWarning - diagnostic execution will cause multiple link flaps on the peer side -advisable to shut directly connected portsProceed with Diags [confirm yes/no]: yes% Error: Invalid command - card is not present.% Error: Invalid command - card must be offline.% Error: Invalid command - card is not present.% Error: Invalid command - card is not present.% Error: Invalid command - card is not present.% Error: Invalid command - card is not present.% Error: Invalid command - card is not present.% Error: Invalid command - card is not present.% Error: Invalid command - card is not present.Dell#Apr 26 22:32:01: %C9000LC0640:4 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags onlinecard 42d3h3m : Approximate time to complete the Diags (all levels)... 10 MinsApr 26 22:32:01: %C9000LC0640:5 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags onlinecard 52d3h3m : Approximate time to complete the Diags (all levels)... 10 MinsApr 26 22:32:01: %C9000-RPM-2.56T:10 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags onlinecard 102d3h3m : Approximate time to complete the Diags (all levels)... 10 MinsApr 26 22:32:01: %SYSTEM:LP %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on CP unit2d3h3m : Approximate time to complete the Diags (all levels)... 10 MinsApr 26 22:33:07: %RPM0-P:CP %IPC-2-STATUS: target line card 10 not respondingApr 26 22:33:07: %RPM0-P:CP %CHMGR-2-LINECARD_DOWN: Major alarm: linecard 10 down- IPC timeout2d3h4m : Diagnostic test results are stored on file: flash:/TestReport-LP-5.txt2d3h4m : Diagnostic test results are stored on file: flash:/TestReport-LP-4.txtApr 26 22:33:13: %C9000LC0640:5 %DIAGAGT-6-DA_DIAG_DONE: Diags finished onlinecard 52d3h4m : Recommended to reboot the system after diagnostics!!!Apr 26 22:33:14: %C9000LC0640:4 %DIAGAGT-6-DA_DIAG_DONE: Diags finished onlinecard 42d3h4m : Recommended to reboot the system after diagnostics!!!2d3h7m : Diagnostic test results are stored on file: flash:/TestReport-CP-unit.txtApr 26 22:36:01: %SYSTEM:LP %DIAGAGT-6-DA_DIAG_DONE: Diags finished on CP unit2d3h7m : Recommended to reboot the system after diagnostics!!!Dell#dir flash:Directory of flash:1 drwx 4096 Jan 01 1980 00:00:00 +00:00 .2 drwx 2280 Apr 26 2015 22:42:17 +00:00 ..3 d--- 4096 Aug 14 2014 02:26:48 +00:00 ADMIN_DIR4 drwx 12288 Aug 14 2014 02:26:48 +00:00 CORE_DUMP_DIR5 drwx 4096 Sep 12 2014 16:13:24 +00:00 TRACE_LOG_DIR6 drwx 4096 Aug 14 2014 03:00:40 +00:00 DCLI_LOG_DIR7 drwx 4096 Sep 12 2014 16:13:24 +00:00 CONFD_LOG_DIR8 -r-x 0 Nov 30 2014 04:07:40 +00:00 localcfg9 drwx 8192 Sep 12 2014 16:13:24 +00:00 CRASH_LOG_DIR10 drwx 4096 Sep 12 2014 16:13:24 +00:00 RUNTIME_PATCH_DIR11 drwx 4096 Dec 24 2014 14:11:02 +00:00 gdb12 drwx 4096 Sep 25 2014 10:43:12 +00:00 grubdirDebugging and Diagnostics 350