-- Temperature Limits (deg C) -----------------------------------------------------------------------------Minor Off Minor Major Off Major Shutdownlinecard0 78 99 84 105 110---------------------------------------------------------------------------Minor Off Minor Major Off Major ShutdownRPM0 35 40 43 48 NA---------------------------------------------------------------------------Minor Off Minor Major Off Major ShutdownPEid100/Stack0 60 65 72 75 105To display current temperature of line sensors, use the show environment thermal-sensors command.Minor threshold crossings do not cause alarms, but are used to trigger increases in the speed of the systemfans as needed to keep the component temperature within the desired range.Dell#show environment thermal-sensor-- Thermal Sensor Readings (deg C) --Slot 0 1 2 3 4 5 6 7 8 9----------------------------------------------------------------47 47 47 - - - - - 42To get the current sensor temperature of RPM, use the show rpm rpm-id.In the following example, 29C is the CP card’s temperature in RPM. 52C is LP card’s sensor temperature in theRPM.Dell#show rpm 1-- RPM card 1 --Status : activeNext Boot : onlineCard Type : RPM - Route Processor Module (C9000-RPM-2.56T)Hardware Rev : 4.0Num Ports : 1Up Time : 25 min, 39 secLast Restart : normal power-cycleDell Networking OS Version : 1-0(0-4058)Jumbo Capable : yesCP Boot Flash : 3.3.1.15 [booted]RP Boot Flash : 3.3.1.15 [booted]Boot Selector : 3.3.0.0gRP Boot Selector : 3.3.0.0gCP Mem Size : 2127536128 bytesRP Mem Size : 2127536128 bytesTemperature : 29C 52CPower Status : ACVoltage : okSerial Number : NAPart Number : 0CKKCP Rev X00Vendor Id : NADate Code : NACountry Code : NAPiece Part ID : CN-0CKKCP-77931-45N-0008PPID Revision : X00Service Tag : 12GQG02Expr Svc Code : 232 582 233 8Auto reboot : EnabledDebugging and Diagnostics 381