Starting test: showTemperature ......+Board First Thermal Monitor Sensor[0] is 38.0 C+Board First Thermal Monitor Sensor[1] is 33.0 C+Board First Thermal Monitor Sensor[2] is 31.0 C+Board First Thermal Monitor Sensor[3] is 38.0 C+Board First Thermal Monitor Sensor[4] is 34.0 C+Board Second Thermal Monitor Sensor[0] is 40.0 C+Board Second Thermal Monitor Sensor[1] is 45.0 C+Board Second Thermal Monitor Sensor[2] is 36.0 C+Board Second Thermal Monitor Sensor[3] is 34.0 C+Board Second Thermal Monitor Sensor[4] is 35.0 CSensor Temperature : 27 cSensor Temperature : 31 cDDR Temperature 33 cshowTemperature ............................................. PASSStarting test: slotInfoTest ......RPM Slot No 0slotInfoTest ................................................ PASSspiFlashAccessTest .......................................... PASSStarting test: udfAccessTest ......+ Access Test for unit 0 : PASSEDudfAccessTest ............................................... PASSStarting test: usbTest ......-USB "/dev/rsd0d" is not plugged/mounted/formatted; test SKIPPEDusbTest ..................................................... FAILLEVEL 1 DIAGNOSTICcpldRWTest .................................................. PASSextCPLDRWTest ............................................... PASSfanCntrlAccessTest .......................................... PASSStarting test: fanCntrlSpeedTest ......ERROR: Tray[0] fan[0] speed 57% is out of expected range [80-100%]ERROR: Fan speed variation failed for tray[0]FAN TRAY[0] FAN 0 Controller Speed Test FAILERROR: Tray[0] fan[1] speed 57% is out of expected range [80-100%]ERROR: Fan speed variation failed for tray[0]FAN TRAY[0] FAN 1 Controller Speed Test FAILERROR: Tray[0] fan[2] speed 56% is out of expected range [80-100%]ERROR: Tray[0] fan[2] speed 41% is out of expected range [50-70%]ERROR: Fan speed variation failed for tray[0]FAN TRAY[0] FAN 2 Controller Speed Test FAILERROR: Tray[0] fan[3] speed 56% is out of expected range [80-100%]ERROR: Fan speed variation failed for tray[0]FAN TRAY[0] FAN 3 Controller Speed Test FAILERROR: Tray[1] fan[0] speed 57% is out of expected range [80-100%]ERROR: Fan speed variation failed for tray[1]FAN TRAY[1] FAN 0 Controller Speed Test FAILERROR: Tray[1] fan[1] speed 57% is out of expected range [80-100%]ERROR: Fan speed variation failed for tray[1]FAN TRAY[1] FAN 1 Controller Speed Test FAILERROR: Tray[1] fan[2] speed 56% is out of expected range [80-100%]ERROR: Fan speed variation failed for tray[1]FAN TRAY[1] FAN 2 Controller Speed Test FAILERROR: Tray[1] fan[3] speed 57% is out of expected range [80-100%]ERROR: Fan speed variation failed for tray[1]FAN TRAY[1] FAN 3 Controller Speed Test FAILERROR: Tray[2] fan[0] speed 57% is out of expected range [80-100%]ERROR: Fan speed variation failed for tray[2]FAN TRAY[2] FAN 0 Controller Speed Test FAILERROR: Tray[2] fan[1] speed 57% is out of expected range [80-100%]ERROR: Fan speed variation failed for tray[2]FAN TRAY[2] FAN 1 Controller Speed Test FAILERROR: Tray[2] fan[2] speed 56% is out of expected range [80-100%]Debugging and Diagnostics 357