GE Multilin 745 Instruction Manual
Table of Contents 745Generator Management Relayhttp://www.GEindustrial.com/multilin viiGE MultilinVoltage Input ....................................................................................................................................... 7-7Transformer Type Selection .............................................................................................................. 7-8Ambient Temperature Input .............................................................................................................. 7-9Analog Outputs ................................................................................................................................. 7-11Tap Position....................................................................................................................................... 7-11Protection SchemesPrecautions........................................................................................................................................ 7-11Harmonic Restrained Percent Differential....................................................................................... 7-11Instantaneous Differential Protection.............................................................................................. 7-17Phase Time Overcurrent................................................................................................................... 7-18Phase Instantaneous Overcurrent 1 ................................................................................................ 7-20Phase Instantaneous Overcurrent 2 ................................................................................................ 7-20Neutral Time Overcurrent ................................................................................................................ 7-21Neutral Instantaneous Overcurrent 1 .............................................................................................. 7-22Neutral Instantaneous Overcurrent 2 .............................................................................................. 7-23Ground Time Overcurrent................................................................................................................ 7-23Ground Instantaneous Overcurrent 1.............................................................................................. 7-25Ground Instantaneous Overcurrent 2.............................................................................................. 7-26Restricted Ground Fault Polarity Test ............................................................................................. 7-26Restricted Ground Fault Element Test ............................................................................................ 7-27Negative Sequence Time Overcurrent............................................................................................ 7-28Negative Sequence Instantaneous Overcurrent............................................................................. 7-30Frequency .......................................................................................................................................... 7-31Overexcitation ................................................................................................................................... 7-36Insulation Aging ................................................................................................................................ 7-37Tap Monitor Failure .......................................................................................................................... 7-38Auxiliary Protection and Monitoring FunctionsTHD Level Scheme............................................................................................................................ 7-38Harmonic Derating Function ............................................................................................................ 7-39Transformer Overload ...................................................................................................................... 7-40Placing the Relay Into ServicePrecautions........................................................................................................................................ 7-40Procedure .......................................................................................................................................... 7-40APPENDIX Change NotesRevision History .................................................................................................................................. 8-1Changes to the 745 Manual ............................................................................................................... 8-1EU Declaration of ConformityGE Multilin WarrantyWarranty Statement ........................................................................................................................... 8-3INDEX |
Related manuals for GE Multilin 745
GE Multilin MIB Instruction Manual
GE Multilin DFF Instruction Manual
GE Multilin HID Instruction Manual
GE Multilin DBT Instruction Manual
GE Multilin 489 Instruction Manual
GE Multilin MIWII Instruction Manual
GE Multilin 350 Series Instruction Manual
GE Multilin 350 Series Instruction Manual
GE 735 Instruction Manual
GE 750 Instruction Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine