4 - 4 Genie Z-45/22 Part No. 32960Service Manual - Second EditionSection 4 - Scheduled Maintenance ProceduresTABLE A PROCEDURES2 Perform a visual inspection around thefollowing areas. An LPG detector may benecessary to locate propane leaks.Gasoline/LPG models:· LPG tank, hoses and fittings, solenoid shutoffvalve, LPG regulator, and carburetor· gasoline tank, shutoff valve, solenoid shutoffvalve, hoses and fittings, fuel pump andcarburetorDeutz Diesel models:· fuel tank, shutoff valve, hoses and fittings, fuelpump, fuel filter, fuel injection pumps and fuelinjectorsIf a fuel leak is discovered, keepany additional personnel fromentering the area and do notoperate the machine. Repair theleak immediately.A-7Check the Hydraulic Oil LevelMaintaining hydraulic oil at the proper level isessential to machine operation. Improper hydraulicoil levels can damage hydraulic components. Dailychecks allow the inspector to identify changes inoil level that might indicate the presence ofhydraulic system problems.1 Be sure that the machine is in the fully stowedposition, then visually inspect the sight gaugelocated on the side of the hydraulic oilreservoir.Result: The hydraulic oil level should be withinthe top 2 inches (5cm) of the sight gauge.Hydraulic oil specificationsHydraulic oil type Dexron II equivalentTank capacity 25 gallons95 litersHydraulic system 30 gallons(including tank) 114 litersA-8Check for Hydraulic LeaksDetecting hydraulic fluid leaks is essential tooperational safety and good machineperformance. Undiscovered leaks can develop intohazardous situations, impair machine functionsand damage machine components.1 Inspect for hydraulic oil puddles, dripping orresidue on or around the following areas:· hydraulic tank—filter, fittings, hoses andturntable surface· engine compartment—fittings, hoses, auxiliarypower unit, main pump and turntable surface· all hydraulic cylinders· all hydraulic manifolds· primary and secondary booms· the underside of the chassis· ground area under the machine800-610-4101ActionRental.com