Part No. 32960 Genie Z-45/22 4 - 23Service Manual - Second Edition Section 4 - Scheduled Maintenance ProceduresTABLE B PROCEDURESB-25Test Drive Speed - StowedPositionProper drive function movement is essential tosafe machine operation. The drive function shouldrespond quickly and smoothly to operator control.Drive performance should also be free ofhesitation, jerking and unusual noise over theentire proportionally controlled speed range.Select a test area that is firm,level and free of obstructions.1 Create start and finish lines by marking twolines on the ground 20 feet (6m) apart.2 Start the engine from the platform controls, andthen select high drive mode (machine on flatground).3 Move the engine speed control switch to highidle (rabbit & foot switch), and then fully lowerthe boom into the stowed position.4 Choose a point on the machine; i.e., contactpatch of a rear tire, as a visual reference foruse when crossing the start and finish lines.5 Bring the machine to top drive speed beforereaching the start line. Begin timing when yourreference point on the machine crosses thestart line.6 Continue at full speed and note the time whenthe machine reference point passes over thefinish line.Specifications: stowed position, high rangeDistance: 20 feet / 6 meters4WD 2.85 seconds (±0.25 seconds)2WD 2.75 seconds (±0.25 seconds)B-26Test the Alarm Package(optional equipment)The alarm package includes:· travel alarm· descent alarm· flashing beaconAlarms and beacons are installed to alertoperators and ground personnel of machineproximity and motion. The alarm packagecomponents are installed on the right side, on topof the turntable cover.The alarm and beacons willoperate with the enginerunning or not.1 At the ground controls pull out the EmergencyStop button to theon position and turn the keyswitch to ground control.Result: The flashing beacon should be on andflashing.2 Move the primary boom switch to thedownposition, hold for a moment and then release it.Now move the secondary boom switch to thedown position, hold for a moment and thenrelease it.Result: The descent alarm should sound wheneach switch is held down.3 Turn the key switch to platform control, thenfrom the platform controls, pull out theEmergency Stop button to theon position.Result: The flashing beacon should be on andflashing.800-610-4101ActionRental.com