Part No. 32960 Genie Z-45/22 4 - 13Service Manual - Second Edition Section 4 - Scheduled Maintenance ProceduresTABLE B PROCEDURESB-6Check the Hydraulic Tank FilterCondition IndicatorMaintaining the hydraulic reservoir filter in goodcondition is essential to good system performanceand safe machine operation. The filter conditionindicator will show when the hydraulic flow isbypassing a clogged filter. If the filter is notfrequently checked and replaced, impurities willremain in the hydraulic system and causecomponent damage.1 Start the engine from the platform controls.2 Switch the engine speed control to high idle(rabbit symbol).3 Inspect the filter condition indicator.a filter condition indicatorb filterc hydraulic reservoirResult: The filter should be operating in thegreen area. If the display showsred, thisindicates that the hydraulic filter is beingbypassed and the filter should be replaced.abcB-7Inspect the Electrical WiringMaintaining electrical wiring in good condition isessential to safe operation and good machineperformance. Failure to find and replace burnt,chafed, corroded or pinched wires could result inunsafe operating conditions and may causecomponent damage.Electrocution hazard. Contact withhot or live circuits may result indeath or serious injury. Removeall rings, watches and otherjewelry.1 Inspect the following areas for burnt, chafed,corroded and loose wires:· engine compartment relay panel· engine wiring harness· inside of the ground control box· turntable manifold wiring2 Start the engine from the ground controls, andthen raise the secondary boom until the upperpivot is above the turntable covers.3 Inspect the upper pivot area for burnt, chafedand pinched cables.4 Fully lower the boom into the stowed positionand turn the engine off.5 Inspect the following areas for burnt, chafed,corroded, pinched and loose wires:· cable track on the primary and secondarybooms· primary boom to platform cable harness· inside of the platform control box800-610-4101ActionRental.com