1-8Operation Command DescriptionLog hostdirectioninfo-center timestamp loghostdateSet the time stampformat in the outputdirection of theinformation center todateNon log hostdirectioninfo-center timestamp { log | trap| debugging } dateRequiredUse either commandSet to display the UTC time zone in theoutput information of the informationcenterinfo-center timestamp utcRequiredBy default, no UTC timezone is displayed in theoutput informationSetting to Output System Information to the ConsoleSetting to output system information to the consoleTable 1-7 Set to output system information to the consoleOperation Command DescriptionEnter system view system-view —Enable the information center info-center enable OptionalEnabled by default.Enable system informationoutput to the consoleinfo-center console channel{ channel-number | channel-name }OptionalBy default, the switch uses informationchannel 0 to outputlog/debugging/trap information to theconsole.Configure the output rules ofsystem informationinfo-center source { modu-name |default } channel{ channel-number | channel-name }[ { log | trap | debug } { levelseverity | state state } ]*OptionalRefer to Table 1-8 for the defaultoutput rules of system information.Set the format of time stamp inthe output informationinfo-center timestamp { log | trap| debugging } { boot | date |none }OptionalBy default, the time stamp format ofthe log and trap output information isdate, and that of the debugging outputinformation is boot.To view the debugging information of some modules on the switch, you need to set the type of theoutput information to debug when configuring the system information output rules, and use thedebugging command to enable debugging for the corresponding modules.