Result Test-specific stringFailed Adapter in slot n; internal errorwhere n is the slot number of the failing adapter.Action:1. Run the ServeRAID Configuration Utility program.2. If the problem persists, replace the ServeRAID adapter in slot n.If the problem persists, have the system serviced.Failed Adapter in slot n; memory allocation errorwhere n is the slot number of the failing adapter.Action: Have the system serviced.Failed Adapter in slot n; PCI configuration errorwhere n is the slot number of the failing adapter.Action: Replace the ServeRAID adapter in slot n. If the problem persists, have thesystem serviced.Failed Adapter in slot n; POST errorwhere n is the slot number of the failing adapter.Action: Replace the ServeRAID adapter in slot n. If the problem persists, have thesystem serviced.Failed Logical drive m on adapter in slot nwhere m is the number of the failing logical drive and n is the slot number of theadapter.Action:1. Run the ServeRAID Configuration Utility program.2. If the problem persists, replace the ServeRAID adapter in slot n.If the problem persists, have the system serviced.Failed Logical drive on system board adapterAction: Run the ServeRAID Configuration Utility program. If the problem persists,have the system serviced.Failed On system board; adapter/drive configuration errorAction: Run the ServeRAID Configuration Utility program. If the problem persists,have the system serviced.Failed On system board; internal errorAction: Run the ServeRAID Configuration Utility program. If the problem persists,have the system serviced.Failed On system board; memory allocation errorAction: Have the system serviced.Failed On system board; PCI configuration errorAction: Have the system serviced.Failed On system board; POST errorAction: Have the system serviced.Failed SCSI drive in bay #n, SCSI ID mwhere n is the bay number of the failing drive and m is the SCSI ID of the drive.Action: Check the cable and power connections on the drive. If the problempersists, have the system serviced.Failed SCSI drive on adapter in slot n, SCSI ID mwhere n is the slot number of the adapter and m is the SCSI ID of the drive.Action: Check the cable and power connections on the drive. If the problempersists, have the system serviced.Chapter 6. Solving problems 129