Result Test-specific stringFailed Test setup error: Application microprocessor not installed or BIOS setup problemAction:1. Verify that the application microprocessor is installed and seated correctly.2. Check the system error log for related error messages.3. If your server does not have the latest level of BIOS installed, update the BIOSto the latest level. Refer to Chapter 7, “Getting help, service, and information”on page 161 for information about obtaining updates.4. If the problem persists, replace the application microprocessor and run themicroprocessor diagnostic program again.If the problem persists, have the system serviced.Failed VRM corresponding to Microprocessor in socket id xyz is defectivewhere xyz identifies the microprocessor whose VRM is causing the error message.Action: Replace the VRM.If the problem persists, have the system serviced.Failed VRM corresponding to Microprocessor in socket id xyz is not installedwhere xyz identifies the microprocessor whose VRM is not installed.Action: Install a VRM.If the problem persists, have the system serviced.Function: Advanced System Management Processor messages(165)Result Test-specific stringNote: If you receive any diagnostic error messages that are not shown in this table, make sure thatyour server has the latest levels of BIOS, Advanced System Management Processor, and diagnosticsmicrocode installed. If the problem persists, have the system serviced.Failed Advanced System Management Processor on system boardAction: Have the system serviced.Function: thermal system messages (175)Function Test-specific stringNote: If you receive any diagnostic error messages that are not shown in this table, make sure thatyour server has the latest levels of BIOS, Advanced System Management Processor, and diagnosticsmicrocode installed. If the problem persists, have the system serviced.Failed Fan #nwhere n is the number of the failing fan.Note: The Fann LED on the diagnostic LED panel will also be on.Action: Replace the indicated fan.Failed Temperature sensed on processor board is out of rangeAction: If one of the fan LEDs on the diagnostic LED panel is on, replace theindicated fan.If the problem persists, have the system serviced.Chapter 6. Solving problems 131