Xen Topaz Programming Manual 10Introduction to ProgrammingBefore you Start Programmingshows Time & date with Extension number.4. Re-start (HOT Start)This mode may be selected in case of re-start (System Reset). The existing System Software(stored to the Flash Memory) and the Customer data (stored to the RAM) will be remained.♦ When the system requires to Re-Start (System Reset), the operation is as follows;1) SW1 on the 308M unit will be set at the right side to “H” and turn System Power Switch to ON.2) Wait until 1-2 minutes, LED2(RUN) is going to be lit and the Key Telephone’s display showsTime & date with Extension number.Before ProgrammingBefore the programming, the Main Software Version and Port Number can be checked by the Dis-play Key Telephone.1. Confirmation of the Software VersionThe Software Version can be checked by “OPAC” key and “Dial 3”(by On-Hook condition) or PRG90-16-01.2. Confirmation of the Port NumberThe Own Port Number can be checked by Press “CHECK” key and “CALL” key (by On-Hook condi-tion). The Other Port Number also can be checked by Press “CHECK” key and Dial Destination Exten-sion Number (by On-Hook condition).3. Concept of Slot NumbersSlot Number will be fixed as followings and EXIFU Slots has no slot number.4. Concept of Trunk/Extension PortsThe system decides the regulation of software port calculation as below;- 308M/308E Unit = Up to 3 Trunk Ports and 8 Extension Ports- 008E Unit = Up to 8 Extension Ports5. Port Calculation for Trunk and/or ExtensionIn case the Trunk and/or Extension Interface Card (308M,308E or 008E) is Installed to a slot, the sys-tem will automatically be detected the type of Interface card, then assign the Trunk port and/or Exten-2 OPBOXSLOT 6SLOT 5SLOT 4SLOT 1(308M)SLOT 2SLOT 3924M