Xen Topaz Programming Manual 36Program 10 to 11PROGRAM 11: SYSTEM NUMBERING11-07: DEPARTMENT GROUP PILOT NUMBERSDescriptionUse Program 11-07 : Department Group Pilot Numbers to assign pilot numbers to each DepartmentGroup set up in Program 16-02. The pilot number is the number users dial for Department Calling and De-partment Step Calling. The pilot number can be up to four digits long. The first/second digit(s) of the numbershould be assigned in Program 11-01 as type 2.DefaultExtension Group Number 1-32: No setting (Extension Group Pilot Number)ConditionsNoneFeature Cross Reference♦ Department Calling♦ Department Step CallingTelephone Programming InstructionsTo enter data for Program 11-07 (Department Group Pilot Numbering):1. Enter the programming mode.2. Enter 11 073. Enter the number of the item you want to program.4. Select the Telephone group number to be programmed by pressing the FLASH or the VOLUME▲ orVOLUME▼ keys.5. Enter data for the item you selected + HOLD.6. Enter data for the next item in the program.ORPress DC once to enter a new item number.ORPress DC until you’ve exited that series’ programming section.INSASBDepartment (Extension) Group Number 1-32Extension GroupPilot Number Description Related ProgramDial (up to 4 digits) ♦ Use this program to assign depart-ment group pilot numbers.♦ The number set up by Program 11-02 (Extension Numbering) cannotbe used.♦ The extension number cannot beduplicated in Programs 11-02, 11-04, 11-06 and 11-08.• 16-01 : Department (Extension)Group Basic Data Setup• 16-02 : Department GroupAssignment forExtensions• 16-03 : Secondary DepartmentGroup11-07-01TEL Gr1Ext Grp No.11-07-xxTEL Grpxxxxxxx