E Series Automated Dispensing System29www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.Setup Menu[SETUP] 1/301 XY Move Speed02 Z Move Speed03 Point to Point Arc Jump04 Park Position05 Calibration Point06 Mark Points07 Program Output Status[SETUP] 2/308 Pause Status09 Auto Purge10 Pre-cycle Initialize11 Pre-dispense Wait Time12 Default Dispense Port13 Needle Detect Setup14 Run Limit[SETUP] 3/315 Measurement Unit16 Password Setup17 Remote Command18 Height Sensor19 Language20 System InformationMenu Item Description01 XY Move Speed Sets the speed of the of X and Y axis movement:• Maximum XY speed: 500 (mm/s) (E2); 800 (mm/s) (E3, E4, E5, E6)• Default: 100 (mm/s)02 Z Move Speed Sets the speed of the of Z axis movement:• Maximum Z speed: 250 (mm/s) (E2); 320 (mm/s) (E3, E4, E5, E6)• Default: 50 (mm/s)03 Point to Point Arc Jump Enables or disables tip movement in an arc motion between dispensepatterns:• 1 Enable: The tip moves in an arc motion.• 2 Disable (default): The tip moves in a square motion.04 Park Position Sets the Park Position XYZ coordinates. When the Park Position commandis used in a dispense program, the tip moves to the set Park Position. The tipalso moves to the Park Position at the end of a dispense program.• Default: 0, 0, 0 (mm)05 Calibration Point Sets a reference point that is used by the system to perform the Needle Adjustfunction.06 Mark Points Sets two reference points that are used by the system to perform the ProgramOffset function.07 Program Output Status Enables or disables how outputs function after a program ends:• 1 Enable: The system keeps outputs ON after a program ends.• 2 Disable (default): The system allows outputs to switch OFF after aprogram ends.08 Pause Status Sets the position that the tip moves to when you press the START button topause the current dispense cycle:• 1 Park Position (default): The tip moves to the user-specified Park Position.• 2 Stand: The tip stays at the current position.09 Auto Purge Used to set up parameters for purging. Refer to “Auto Purge” on page 39.• Purge time: 100.0 (s) maximum• Wait time: 999 (s) maximumContinued on next pageTeach Pendant Menu Item Descriptions (continued)