E Series Automated Dispensing System75www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.Set How Outputs Behave at the End of a ProgramUse Program Output Status under Setup to specify how outputs function after programs end.PREREQUISITES The system is in the Teach Mode. Refer to “How to Switch from Run Mode to Teach Mode” on page 44.# Key Press Step Teach Pendant Display1> >• Press SETUP.• MOVE UP / DOWN to PROGRAMOUTPUT STATUS.• Press ENTER.[SETUP] 1/301 XY Move Speed02 Z Move Speed03 Point to Point Arc Jump04 Park Position05 Calibration Point06 Mark Points07*Program Output Status2or >• Press 1 ENABLE to keep outputs ONafter a program ends.• Press 2 DISABLE (default) to allowoutputs to switch OFF after a programends.Program Output StatusDisable------------------------------1 Enable2 DisableSelect: _[F1] OK3 • Press F1 to save or exit.Automatically Switch Outputs ONUse Initialize Output under Menu1 to specify which outputs (1–8) switch ON at the beginning of programs.NOTE: Online signals must be disabled.PREREQUISITES The system is in the Teach Mode. Refer to “How to Switch from Run Mode to Teach Mode” on page 44.# Key Press Step Teach Pendant Display1> >• Press MENU1.• MOVE UP / DOWN to INITIALIZEOUTPUT• Press ENTER.[MENU 1]01 Group Edit02 Ex. Step & Repeat03 Program Name04 Axis Limit05*Initialize Output06 Jog Acceleration07 Teach Move Z Clearance2>• Use the ARROW keys to move throughthe outputs.• Press ENTER to toggle values: 1 for ON,0 for OFF.Initialize Output------------------------------Port: 12345678Current: 00000000New: 00000000[F1] OK3 • Press F1 to save or exit.