E Series Automated Dispensing System49www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.Working with Programs and Commands (continued)How to Change a Group of Addresses (Group Edit)You can use the selections under Group Edit to make a global change to a batch, or group, of selected addresses ina program.PREREQUISITES The system is in the Teach Mode. Refer to “How to Switch from Run Mode to Teach Mode” on page 44. The program you want to edit is currently open. Refer to “How to Open and Edit a Program” on page 45.# Key Press Step Teach Pendant Display1> >• Press MENU1.• MOVE UP / DOWN to GROUP EDIT.• Press ENTER.[MENU 1] 1/201*Group Edit02 Ex. Step & Repeat03 Program Name04 Axis Limit05 Initialize Output06 Jog Acceleration07 Teach Move Z Clearance2or >oror >Do one of the following:• MOVE UP / DOWN and use the numberkeys to enter the range of addresses.• Press F2 to select all the addresses inthe program.• Press F3 to select all the addressesfrom the current address to the end ofthe program.• Press F1 to continue.Group Edit------------------------------From Address: 1209To Address: 1254[F1] OK [F2] All [F3] End3>or• Press the number for the operation youwant to perform for the specified rangeof addresses, or• Press F2 to move to the next screen.1 — Copies the selected addresses2 — Deletes the selected addresses3 — Moves the selected addresses to anew address numberGroup Edit 1209-1254 1/2------------------------------1 Copy 5 Line Speed2 Delete 6 Z Value3 Move 7 Point Offset4 Dispense Time 8 Offset ToSelect: _[F1] OK [F2] Next4 — For Dispense Dot commands only,changes the Dispense Time valuefor all selected addresses by thespecified percentage.5 — Changes the Line Speed valuefor all selected addresses by thespecified percentage.Continued on next page