E Series Automated Dispensing System45www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.How to Open and Edit a ProgramAll programs have a unique number from 01 to 99. By default, the last program number that was open before thesystem was shut down is the same program number that opens when the system is switched on.PREREQUISITES The system is in the Teach Mode. Refer to “How to Switch from Run Mode to Teach Mode” on page 44.# Key Press Step Teach Pendant Display1> >• Press F1.• MOVE UP / DOWN to PROGRAM LIST.• Press ENTER.[PROGRAM MENU] 1/101 Teach/Run02*Program List03 Reset Counter04 Program Offset05 Needle Adjust06 Auto Needle Adjust2>• MOVE UP / DOWN to select the desiredprogram.• Press ENTER.The selected program becomes thecurrent program and remains open untilanother program number is selected.Program List------------------------------01 0602 0703*EXAMPLE 0804 0905 10[F1] OK3or >• MOVE UP / DOWN to select thecommand line to edit.• Press ENTER.0001 Line Start 10.0,10002 Line Passing 10.0,10003 Arc Point0004*Dispense Dot0005 EMPTY0006 EMPTY0007 EMPTY0008 EMPTY4xxxxx or >• Enter the new coordinates manually.or• Press F3 to update the XYZ values tothe current tip location.• Press F1 to save and exit or ESC tocancel the changes.Dispense Dot 1/3------------------------------X: 130.93 mmY: 37.39 mmZ: 45.54 mm[F1] OK [F2] Next [F3] Current5 • Make other changes as needed.• Press F1 to save and exit.Working with Programs and Commands (continued)