E Series Automated Dispensing System33www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.Axis LimitAxis Limit sets how far the dispensing tip is allowed to move within the XYZ working area. If a command includes apoint that is outside the specified axis limits, an error occurs.# Key Press Step Teach Pendant Display1> >• Press MENU1.• MOVE UP / DOWN to AXIS LIMIT.• Press ENTER.[MENU 1] 1/201 Group Edit02 Ex. Step & Repeat03 Program Name04*Axis Limit05 Initialize Output06 Jog Acceleration07 Teach Move Z Clearance2x >• Enter the desired values.- E2 maximums: 200, 200, 50 mm- E3 maximums: 300, 300, 100 mm- E4 maximums: 400, 400, 100 mm- E5 maximums: 500, 500, 150 mm- E6 maximums: 620, 500, 150 mm• Press F1 to save or exit.or• Press F3 to return to the factory defaultsettings.Axis Limit------------------------------X Limit: 300.00 mmY Limit: 300.00 mmZ Limit: 150.00 mm[F1] OK [F3] DefaultXY Move Speed or Z Move SpeedXY Move Speed is how fast the tip travels along the XY axis. Z Move Speed is how fast the tip moves up or downthe Z axis.# Key Press Step Teach Pendant Display1> >• Press SETUP.• MOVE UP / DOWN toXY MOVE SPEEDorZ MOVE SPEED.• Press ENTER.[SETUP] 1/301*XY Move Speed02 Z Move Speed03 Point to Point Arc Jump04 Park Position05 Calibration Point06 Mark Points07 Program Output Status2 • Enter the desired value.- XY Move Speed range: 0–800 mm/s- Z Move Speed range: 0–320 mm/s• Press F1 to save or exit.XY Move Speed------------------------------Current: 100.0 mm/sNew: _[F1] OKSetting System Parameters (continued)